TY - JOUR
T1 - Assessing the severity of rainfall-derived infiltration and inflow and sewer deterioration based on the flux stability of sewage markers
AU - Shelton, Jessica M.
AU - Kim, Lavane
AU - Fang, Jiasong
AU - Ray, Chittaranjan
AU - Yan, Tao
PY - 2011/10/15
Y1 - 2011/10/15
N2 - This study investigated the flux stability of select chemical and biological sewage markers, including caffeine, total nitrogen (TN), total suspended solids (TSS), E. coli, and enterococci, and their suitability in assessing the severity of rainfall-derived infiltration and inflow (RDII) in a residential sewershed. To quantify and compare marker flux stability, concentrations of the candidate markers in two dry-weather periods were determined and the one-day lag autocorrelation coefficients (r) of their mass fluxes were calculated. TN (r = 0.82-0.88) exhibited higher and more consistent flux stability than TSS (r = 0.49-0.82), caffeine (r = 0.56-0.58), E. coli (r = 0.36-0.87), and enterococci (by culture; r = 0.40-0.52), all of which except enterococci by qPCR (r = -0.10-0.21) showed significant autocorrelation. Sewage flows and marker concentrations were also monitored in two wet-weather periods, and the severity of RDII (R RDII) were calculated using either flow measurements or marker concentrations independently. Corresponding to its outstanding flux stability, R RDII values estimated by TN predicted all severe RDII instances and gave the highest and most consistent correlation (r = 0.74-0.78) among the different sewage markers. Overall, the study illustrated the feasibility of using the flux stability of sewage markers in assessing the severity of RDII and thereby deterioration levels in sewer systems.
AB - This study investigated the flux stability of select chemical and biological sewage markers, including caffeine, total nitrogen (TN), total suspended solids (TSS), E. coli, and enterococci, and their suitability in assessing the severity of rainfall-derived infiltration and inflow (RDII) in a residential sewershed. To quantify and compare marker flux stability, concentrations of the candidate markers in two dry-weather periods were determined and the one-day lag autocorrelation coefficients (r) of their mass fluxes were calculated. TN (r = 0.82-0.88) exhibited higher and more consistent flux stability than TSS (r = 0.49-0.82), caffeine (r = 0.56-0.58), E. coli (r = 0.36-0.87), and enterococci (by culture; r = 0.40-0.52), all of which except enterococci by qPCR (r = -0.10-0.21) showed significant autocorrelation. Sewage flows and marker concentrations were also monitored in two wet-weather periods, and the severity of RDII (R RDII) were calculated using either flow measurements or marker concentrations independently. Corresponding to its outstanding flux stability, R RDII values estimated by TN predicted all severe RDII instances and gave the highest and most consistent correlation (r = 0.74-0.78) among the different sewage markers. Overall, the study illustrated the feasibility of using the flux stability of sewage markers in assessing the severity of RDII and thereby deterioration levels in sewer systems.
UR - http://www.scopus.com/inward/record.url?scp=80054715289&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=80054715289&partnerID=8YFLogxK
U2 - 10.1021/es2019115
DO - 10.1021/es2019115
M3 - Article
C2 - 21902223
AN - SCOPUS:80054715289
SN - 0013-936X
VL - 45
SP - 8683
EP - 8690
JO - Environmental Science and Technology
JF - Environmental Science and Technology
IS - 20
ER -