T1 - Calibrated finger rub auditory screening test (CALFRAST)
AU - Torres-Russotto, D.
AU - Landau, W. M.
AU - Harding, G. W.
AU - Bohne, B. A.
AU - Sun, K.
AU - Sinatra, P. M.
PY - 2009/5/5
Y1 - 2009/5/5
N2 - BACKGROUND: Determination of auditory function is a fundamental part of a complete neurologic examination. Disability from permanent hearing loss is common in the general population. Current bedside auditory tests are unreliable and cumbersome. We evaluated the calibrated finger rub auditory screening test (CALFRAST) as a routine diagnostic tool. METHODS: The sound spectrum and mean peak intensities of standard finger rub were measured, as well as background noise. CALFRAST overlapped the frequency spectrum of normal speech. Patients and companions were recruited from a neurology clinic. With arms extended, two stimulus intensities were presented: strong finger rub (CALFRAST-Strong 70) and the faintest rub that the examiner could hear (CALFRAST-Faint 70). With subjects' eyes closed, each ear's CALFRAST threshold was ascertained and then compared with its audiometric measure. The normal threshold was considered to be 25 dB. Validity, reliability, and discrimination abilities were obtained using standard methods. RESULTS: Two hundred twenty-one subjects (442 ears; 58% women) were examined. Ages ranged from 18 to 88 years, with a mean of 46 years. Eighty-five subjects (39%) had some degree of hearing loss. Both specificity and positive predictive value of CALFRAST-Strong 70 were 100%. Both sensitivity and negative predictive value of CALFRAST-Faint 70 were 99%, with a negative likelihood ratio <0.1. Area under the receiver operating characteristic curve was 0.94, consistent with excellent discrimination ability. Both intrarater and interrater reliability were excellent, both κ >0.8. Subjects' self-assessment of hearing was unreliable. CONCLUSION: The calibrated finger rub auditory screening test (CALFRAST) is simple, accurate, inexpensive, and reliable. As a routine screening tool, CALFRAST may contribute to more efficient identification of auditory impairment.
AB - BACKGROUND: Determination of auditory function is a fundamental part of a complete neurologic examination. Disability from permanent hearing loss is common in the general population. Current bedside auditory tests are unreliable and cumbersome. We evaluated the calibrated finger rub auditory screening test (CALFRAST) as a routine diagnostic tool. METHODS: The sound spectrum and mean peak intensities of standard finger rub were measured, as well as background noise. CALFRAST overlapped the frequency spectrum of normal speech. Patients and companions were recruited from a neurology clinic. With arms extended, two stimulus intensities were presented: strong finger rub (CALFRAST-Strong 70) and the faintest rub that the examiner could hear (CALFRAST-Faint 70). With subjects' eyes closed, each ear's CALFRAST threshold was ascertained and then compared with its audiometric measure. The normal threshold was considered to be 25 dB. Validity, reliability, and discrimination abilities were obtained using standard methods. RESULTS: Two hundred twenty-one subjects (442 ears; 58% women) were examined. Ages ranged from 18 to 88 years, with a mean of 46 years. Eighty-five subjects (39%) had some degree of hearing loss. Both specificity and positive predictive value of CALFRAST-Strong 70 were 100%. Both sensitivity and negative predictive value of CALFRAST-Faint 70 were 99%, with a negative likelihood ratio <0.1. Area under the receiver operating characteristic curve was 0.94, consistent with excellent discrimination ability. Both intrarater and interrater reliability were excellent, both κ >0.8. Subjects' self-assessment of hearing was unreliable. CONCLUSION: The calibrated finger rub auditory screening test (CALFRAST) is simple, accurate, inexpensive, and reliable. As a routine screening tool, CALFRAST may contribute to more efficient identification of auditory impairment.
UR - http://www.scopus.com/inward/record.url?scp=67649410670&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=67649410670&partnerID=8YFLogxK
U2 - 10.1212/WNL.0b013e3181a41280
DO - 10.1212/WNL.0b013e3181a41280
M3 - Article
C2 - 19414727
AN - SCOPUS:67649410670
SN - 0028-3878
VL - 72
SP - 1595
EP - 1600
JO - Neurology
JF - Neurology
IS - 18
ER -