T1 - Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes
AU - Prospero Ponce, Claudia Maria
AU - Rocha, Karolinne Maia
AU - Smith, Scott D.
AU - Krueger, Ronald R.
N1 - Funding Information:
Supported by a challenge grant to the Department of Ophthalmology, Cleveland Clinic Lerner College of Medicine, from Research to Prevent Blindness, New York, New York, USA.
PY - 2009/6
Y1 - 2009/6
N2 - Purpose: To compare central (CCT) and peripheral corneal thickness (PCT) using Scheimpflug imaging (Pentacam), high-speed optical coherence tomography (Visante OCT), and ultrasound (US) pachymetry (Sonogage Corneo-Gage Plus) in normal, keratoconus-suspect, and post-laser in situ keratomileusis (LASIK) eyes. Setting: Department of Refractive Surgery, Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA. Methods: The CCT and PCT were retrospectively measured using US pachymetry, Scheimpflug imaging, and high-speed OCT from January 2006 to March 2008. The influence of age and absolute magnitude of corneal thickness were also analyzed. Analysis was by multivariate generalized estimating equations, multivariate linear regression, and linear regression plots. Results: One hundred sixty-three eyes were analyzed. Ultrasound pachymetry CCT measurements were consistently higher than Scheimpflug and OCT measurements (mean difference 6.5 μm ± 1.8 [SD] and 7.5 ± 1.4 μm, respectively) (both P<.0005) in normal eyes; the difference was statistically similar and not greater with keratoconus suspicion, age, or absolute magnitude of corneal thickness (P>.05). Scheimpflug measurements were significantly lower than US pachymetry in post-LASIK eyes (P<.0005). There was no statistically significant difference (mean 0.9 ± 1.4 μm) in Scheimpflug and OCT CCT measurements (P>.5), although Scheimpflug measurements were significantly lower in post-LASIK eyes (P<.0005). Scheimpflug PCT measurements were higher than OCT measurements, showing more agreement with increasing age (P = .017). Conclusions: Scheimpflug and OCT CCT measurements were reproducible but always thinner than US pachymetry in normal and keratoconus-suspect eyes. In post-LASIK eyes, OCT pachymetry maps were more accurate than Scheimpflug maps. The influence of age on PCT requires further study.
AB - Purpose: To compare central (CCT) and peripheral corneal thickness (PCT) using Scheimpflug imaging (Pentacam), high-speed optical coherence tomography (Visante OCT), and ultrasound (US) pachymetry (Sonogage Corneo-Gage Plus) in normal, keratoconus-suspect, and post-laser in situ keratomileusis (LASIK) eyes. Setting: Department of Refractive Surgery, Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA. Methods: The CCT and PCT were retrospectively measured using US pachymetry, Scheimpflug imaging, and high-speed OCT from January 2006 to March 2008. The influence of age and absolute magnitude of corneal thickness were also analyzed. Analysis was by multivariate generalized estimating equations, multivariate linear regression, and linear regression plots. Results: One hundred sixty-three eyes were analyzed. Ultrasound pachymetry CCT measurements were consistently higher than Scheimpflug and OCT measurements (mean difference 6.5 μm ± 1.8 [SD] and 7.5 ± 1.4 μm, respectively) (both P<.0005) in normal eyes; the difference was statistically similar and not greater with keratoconus suspicion, age, or absolute magnitude of corneal thickness (P>.05). Scheimpflug measurements were significantly lower than US pachymetry in post-LASIK eyes (P<.0005). There was no statistically significant difference (mean 0.9 ± 1.4 μm) in Scheimpflug and OCT CCT measurements (P>.5), although Scheimpflug measurements were significantly lower in post-LASIK eyes (P<.0005). Scheimpflug PCT measurements were higher than OCT measurements, showing more agreement with increasing age (P = .017). Conclusions: Scheimpflug and OCT CCT measurements were reproducible but always thinner than US pachymetry in normal and keratoconus-suspect eyes. In post-LASIK eyes, OCT pachymetry maps were more accurate than Scheimpflug maps. The influence of age on PCT requires further study.
UR - http://www.scopus.com/inward/record.url?scp=67249126267&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=67249126267&partnerID=8YFLogxK
U2 - 10.1016/j.jcrs.2009.01.022
DO - 10.1016/j.jcrs.2009.01.022
M3 - Article
C2 - 19465292
AN - SCOPUS:67249126267
SN - 0886-3350
VL - 35
SP - 1055
EP - 1062
JO - Journal of cataract and refractive surgery
JF - Journal of cataract and refractive surgery
IS - 6
ER -