TY - JOUR
T1 - Consistency of rapid muscle force characteristics
T2 - Influence of muscle contraction onset detection methodology
AU - Thompson, Brennan J.
AU - Ryan, Eric D.
AU - Herda, Trent J.
AU - Costa, Pablo B.
AU - Walter, Ashley A.
AU - Sobolewski, Eric J.
AU - Cramer, Joel T.
PY - 2012/12
Y1 - 2012/12
N2 - The purpose of this study was to investigate the consistency of commonly reported rapid force characteristics utilizing both automated and manual muscle contraction onset detection methods. Twenty-four healthy volunteers performed isometric strength testing of the plantar flexor muscle group on two nonconsecutive days. Test-retest reliability was evaluated using intraclass correlation coefficients (ICCs), standard errors of measurement (SEM), and the SEM as a percentage of the mean (SEM%) for rate of force development (RFD), relative RFD, contractile impulse, and absolute force-time values at various epoch durations using automated and manual onset detection methods. For all rapid force variables, ICC and SEM% values ranged from 0.52 to 0.96 and 7.56% to 37.56%, respectively. For the majority of these variables (20 of 23), the automated onset detection method resulted in higher ICC and lower SEM% values compared to the manual onset detection method. Regardless of onset detection methodology, the consistency of relative RFD values declined following 50% of MVC. Collectively, these findings indicated that commonly evaluated rapid muscle force variables demonstrated acceptable relative and absolute consistency values. However, these values were generally superior for the automated onset detection methodology. Additionally, the consistency of relative RFD values declines following 50% MVC and therefore should be evaluated with caution.
AB - The purpose of this study was to investigate the consistency of commonly reported rapid force characteristics utilizing both automated and manual muscle contraction onset detection methods. Twenty-four healthy volunteers performed isometric strength testing of the plantar flexor muscle group on two nonconsecutive days. Test-retest reliability was evaluated using intraclass correlation coefficients (ICCs), standard errors of measurement (SEM), and the SEM as a percentage of the mean (SEM%) for rate of force development (RFD), relative RFD, contractile impulse, and absolute force-time values at various epoch durations using automated and manual onset detection methods. For all rapid force variables, ICC and SEM% values ranged from 0.52 to 0.96 and 7.56% to 37.56%, respectively. For the majority of these variables (20 of 23), the automated onset detection method resulted in higher ICC and lower SEM% values compared to the manual onset detection method. Regardless of onset detection methodology, the consistency of relative RFD values declined following 50% of MVC. Collectively, these findings indicated that commonly evaluated rapid muscle force variables demonstrated acceptable relative and absolute consistency values. However, these values were generally superior for the automated onset detection methodology. Additionally, the consistency of relative RFD values declines following 50% MVC and therefore should be evaluated with caution.
KW - Force-time curve
KW - Muscle strength
KW - Plantar flexors
KW - Reliability
UR - http://www.scopus.com/inward/record.url?scp=84868213608&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84868213608&partnerID=8YFLogxK
U2 - 10.1016/j.jelekin.2012.05.008
DO - 10.1016/j.jelekin.2012.05.008
M3 - Article
C2 - 22765889
AN - SCOPUS:84868213608
SN - 1050-6411
VL - 22
SP - 893
EP - 900
JO - Journal of Electromyography and Kinesiology
JF - Journal of Electromyography and Kinesiology
IS - 6
ER -