Abstract
In a cross-sectional study of 50 consecutive primary open-angle glaucoma cases, full threshold 30-2 visual fields on Humphrey Visual Field Analyser were correlated to stereometric parameters obtained using a scanning laser ophthalmoscope (HRT II). The strength of linear correlation between the stereometric parameters and visual thresholds was used to generate a correspondence map between the optic disc and the visual field. Rim/disc area ratio and cup/disc area ratio correlated with the visual thresholds at the highest number of points in the visual fields. Thresholds at superior hemifield locations correlated best with the rim/disc area ratio and cup/disc area ratio in the inferonasal sector and the ones in the inferior hemifield correlated best with the rim/disc area ratio and cup/disc area ratio in the superotemporal sector. Optic disc parameters correlated better with inferior field locations and non-edge points than superior field locations and edge points. The data indicate that rim/disc area ratio and cup/disc area ratio measurements on HRT II have a good correlation with visual field damage seen on automated visual fields.
Original language | English (US) |
---|---|
Pages (from-to) | 233-242 |
Number of pages | 10 |
Journal | Ophthalmic and Physiological Optics |
Volume | 23 |
Issue number | 3 |
DOIs | |
State | Published - May 2003 |
Externally published | Yes |
Keywords
- Glaucoma
- HRT 11
- Humphrey Visual Field Analyser
- Retinotopy
- Scanning laser ophthalmoscope
- Visual field