TY - JOUR
T1 - Cyclophosphoramidate ion as mass defect marker for efficient detection of protein serine phosphorylation
AU - Shi, Yu
AU - Bajrami, Bekim
AU - Morton, Martha
AU - Yao, Xudong
PY - 2008/10/1
Y1 - 2008/10/1
N2 - A novel method is reported to modify the phosphate groups on phosphoserine peptides to the corresponding phosphoramidates, using 2-aminobenzylamine. Upon collision-induced dissociation, the modified peptides release the positively charged phosphoramidate that via gas-phase intramolecular elimination forms a cyclophosphoramidate (CyPAA) ion, the protonated form of 1,4-dihydro-2-hydroxy- 2-oxobenzo[3,1,2]oxazaphosphorine. The positive nature of the ion eliminates the need for real-time instrument polarity switching and greatly increases the versatility of commonly used mass spectrometers for phosphopeptide analysis. This ion has sufficient mass defect, due to containing a phosphorus atom and a high content of oxygen atoms, which makes mass spectrometers of medium mass resolution and accuracy adequate for separating the ion from isobaric interfering ions. The specificity of the CyPAA ion for detecting phosphoserine peptides in complex peptide mixtures is comparable to the specificity of the phosphotyrosine immonium ion for phosphotyrosine peptides, allowing the efficient data complexity reduction for fast and focused analysis of phosphoserine-containing peptides.
AB - A novel method is reported to modify the phosphate groups on phosphoserine peptides to the corresponding phosphoramidates, using 2-aminobenzylamine. Upon collision-induced dissociation, the modified peptides release the positively charged phosphoramidate that via gas-phase intramolecular elimination forms a cyclophosphoramidate (CyPAA) ion, the protonated form of 1,4-dihydro-2-hydroxy- 2-oxobenzo[3,1,2]oxazaphosphorine. The positive nature of the ion eliminates the need for real-time instrument polarity switching and greatly increases the versatility of commonly used mass spectrometers for phosphopeptide analysis. This ion has sufficient mass defect, due to containing a phosphorus atom and a high content of oxygen atoms, which makes mass spectrometers of medium mass resolution and accuracy adequate for separating the ion from isobaric interfering ions. The specificity of the CyPAA ion for detecting phosphoserine peptides in complex peptide mixtures is comparable to the specificity of the phosphotyrosine immonium ion for phosphotyrosine peptides, allowing the efficient data complexity reduction for fast and focused analysis of phosphoserine-containing peptides.
UR - http://www.scopus.com/inward/record.url?scp=54749085464&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=54749085464&partnerID=8YFLogxK
U2 - 10.1021/ac801355u
DO - 10.1021/ac801355u
M3 - Article
C2 - 18781815
AN - SCOPUS:54749085464
SN - 0003-2700
VL - 80
SP - 7614
EP - 7623
JO - Analytical chemistry
JF - Analytical chemistry
IS - 19
ER -