T1 - Demand controlled ventilation for multiple zone HVAC systems
T2 - CO2-based dynamic reset (RP 1547)
AU - Lin, Xingbin
AU - Lau, Josephine
PY - 2014/11/15
Y1 - 2014/11/15
N2 - Demand controlled ventilation (DCV) is used to reduce the system outdoor airflow (OA) when the occupancy of the system is under design occupancy. However, the new versions of ASHRAE Standard 62.1-2010 make DCV more difficult to implement for multiple zone HVAC systems. This article proposes a CO2-based and occupancy-sensor-based dynamic reset of OA rate for multiple zone HVAC systems ("CO2-based DR"). This control strategy uses bioeffluent load estimation with a steady-state assumption to calculate and dynamically reset the system OA rate minimum set-point by solving the multiple-zone system equations for current conditions. Building energy and airflow simulations were implemented to assess the energy performance and indoor air quality of this control strategy. The simulation results showed that the average annual system OA rate for CO2-based DR is 14.6% less than the OA rate for without DCV, in which case the system OA is always maintained as constant. The annual monetary saving as a percentage of the baseline case (without DCV) is between 0.3% and 11.0% for 16 climate zones in the United States.
AB - Demand controlled ventilation (DCV) is used to reduce the system outdoor airflow (OA) when the occupancy of the system is under design occupancy. However, the new versions of ASHRAE Standard 62.1-2010 make DCV more difficult to implement for multiple zone HVAC systems. This article proposes a CO2-based and occupancy-sensor-based dynamic reset of OA rate for multiple zone HVAC systems ("CO2-based DR"). This control strategy uses bioeffluent load estimation with a steady-state assumption to calculate and dynamically reset the system OA rate minimum set-point by solving the multiple-zone system equations for current conditions. Building energy and airflow simulations were implemented to assess the energy performance and indoor air quality of this control strategy. The simulation results showed that the average annual system OA rate for CO2-based DR is 14.6% less than the OA rate for without DCV, in which case the system OA is always maintained as constant. The annual monetary saving as a percentage of the baseline case (without DCV) is between 0.3% and 11.0% for 16 climate zones in the United States.
UR - http://www.scopus.com/inward/record.url?scp=84910620386&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84910620386&partnerID=8YFLogxK
U2 - 10.1080/10789669.2014.945853
DO - 10.1080/10789669.2014.945853
M3 - Article
AN - SCOPUS:84910620386
VL - 20
SP - 875
EP - 888
JO - Science and Technology for the Built Environment
JF - Science and Technology for the Built Environment
SN - 2374-4731
IS - 8
ER -