TY - JOUR
T1 - Distal embolization as a presenting symptom of aortic aneurysms
AU - Baxter, B. Timothy
AU - McGee, Gregory S.
AU - Flinn, William R.
AU - McCarthy, Walter J.
AU - Pearce, William H.
AU - Yao, James S.T.
PY - 1990/8
Y1 - 1990/8
N2 - The records of 302 patients who underwent abdominal aortic aneurysm (AAA) repair between 1985 and 1990 were reviewed. Two hundred and forty-eight patients (82%) were asymptomatic, while 32 patients (11%) had ruptured aneurysms. During this period, 15 patients (5%) presented with distal embolization as the first manifestation of their AAA. The preoperative embolic event resulted in limb-threatening ischemia in 3 patients, digital ischemia in 11, and calf myonecrosis in 1. CT scan was performed in 14 of 15 patients demonstrating irregular, heterogeneous thrombus within the AAA. Only two of the AAAs were larger than 5 cm. Angiography demonstrated occlusive lesions but was not diagnostic for AAA in seven patients and resulted in three episodes of embolization. AAA was repaired with a tube graft in 4 patients while a bifurcated graft was required in 11 patients for aneurysmal (in 4 patients) and occlusive disease (in 7 patients) of the iliac arteries. All cases employed a transperitoneal approach, systemic heparin, and distal occlusion prior to aortic clamping. Complications included three major (below-knee) and five minor amputations, developing or worsening renal failure in five patients (33%), and death in two (13%). In comparison, mortality was 5% for elective repair and 66% for rupture during this same period. CT scan was safer and more informative than angiography. The morbidity of patients with AAA presenting with emboli is comparable with rupture. The risk of embolization does not correlate with size and indicates the potentially dangerous nature of small AAAs.
AB - The records of 302 patients who underwent abdominal aortic aneurysm (AAA) repair between 1985 and 1990 were reviewed. Two hundred and forty-eight patients (82%) were asymptomatic, while 32 patients (11%) had ruptured aneurysms. During this period, 15 patients (5%) presented with distal embolization as the first manifestation of their AAA. The preoperative embolic event resulted in limb-threatening ischemia in 3 patients, digital ischemia in 11, and calf myonecrosis in 1. CT scan was performed in 14 of 15 patients demonstrating irregular, heterogeneous thrombus within the AAA. Only two of the AAAs were larger than 5 cm. Angiography demonstrated occlusive lesions but was not diagnostic for AAA in seven patients and resulted in three episodes of embolization. AAA was repaired with a tube graft in 4 patients while a bifurcated graft was required in 11 patients for aneurysmal (in 4 patients) and occlusive disease (in 7 patients) of the iliac arteries. All cases employed a transperitoneal approach, systemic heparin, and distal occlusion prior to aortic clamping. Complications included three major (below-knee) and five minor amputations, developing or worsening renal failure in five patients (33%), and death in two (13%). In comparison, mortality was 5% for elective repair and 66% for rupture during this same period. CT scan was safer and more informative than angiography. The morbidity of patients with AAA presenting with emboli is comparable with rupture. The risk of embolization does not correlate with size and indicates the potentially dangerous nature of small AAAs.
UR - http://www.scopus.com/inward/record.url?scp=0025222254&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025222254&partnerID=8YFLogxK
U2 - 10.1016/S0002-9610(05)80306-X
DO - 10.1016/S0002-9610(05)80306-X
M3 - Article
C2 - 2200293
AN - SCOPUS:0025222254
SN - 0002-9610
VL - 160
SP - 197
EP - 201
JO - The American Journal of Surgery
JF - The American Journal of Surgery
IS - 2
ER -