TY - JOUR
T1 - Effect of redox label tether length and flexibility on sensor performance of displacement-based electrochemical DNA sensors
AU - Yu, Zhi gang
AU - Zaitouna, Anita J.
AU - Lai, Rebecca Y.
N1 - Funding Information:
This research was supported by Nebraska EPSCoR ( EPS-1004094 ) and the National Science Foundation ( CHE-0955439 ).
PY - 2014/2/17
Y1 - 2014/2/17
N2 - This article summarizes the sensor performance of four electrochemical DNA sensors that exploit the recently developed displacement-replacement sensing motif. In the absence of the target, the capture probe is partially hybridized to the signaling probe at the distal end, positioning the redox label, methylene blue (MB), away from the electrode. In the presence of the target, the MB-modified signaling probe is released; one type of probe is capable of assuming a stem-loop probe (SLP) conformation, whereas the other type adopts a linear probe (LP) conformation. Independent of the sensor architecture, all four sensors showed "signal-on" sensor behavior. Unlike the previous report, here we focused on elucidating the effect of the redox label tether length and flexibility on sensor sensitivity, specificity, selectivity, and reusability. For both SLP and LP sensors, the limit of detection was 10. pM for sensors fabricated using a signaling probe with three extra thymine (T3) bases linked to the MB label. A limit of detection of 100. pM was determined for sensors fabricated using a signaling probe with five extra thymine (T5) bases. The linear dynamic range was between 10. pM and 100. nM for the T3 sensors, and between 100. pM and 100. nM for the T5 sensors. When compared to the LP sensors, the SLP sensors showed higher signal enhancement in the presence of the full-complement target. More importantly, the SLP-T5 sensor was found to be highly specific; it is capable of discriminating between the full complement and single-base mismatch targets even when employed in undiluted blood serum. Overall, these results highlight the advantages of using oligo-T(s) as a tunable linker to control flexibility of the tethered redox label, so as to achieve the desired sensor response.
AB - This article summarizes the sensor performance of four electrochemical DNA sensors that exploit the recently developed displacement-replacement sensing motif. In the absence of the target, the capture probe is partially hybridized to the signaling probe at the distal end, positioning the redox label, methylene blue (MB), away from the electrode. In the presence of the target, the MB-modified signaling probe is released; one type of probe is capable of assuming a stem-loop probe (SLP) conformation, whereas the other type adopts a linear probe (LP) conformation. Independent of the sensor architecture, all four sensors showed "signal-on" sensor behavior. Unlike the previous report, here we focused on elucidating the effect of the redox label tether length and flexibility on sensor sensitivity, specificity, selectivity, and reusability. For both SLP and LP sensors, the limit of detection was 10. pM for sensors fabricated using a signaling probe with three extra thymine (T3) bases linked to the MB label. A limit of detection of 100. pM was determined for sensors fabricated using a signaling probe with five extra thymine (T5) bases. The linear dynamic range was between 10. pM and 100. nM for the T3 sensors, and between 100. pM and 100. nM for the T5 sensors. When compared to the LP sensors, the SLP sensors showed higher signal enhancement in the presence of the full-complement target. More importantly, the SLP-T5 sensor was found to be highly specific; it is capable of discriminating between the full complement and single-base mismatch targets even when employed in undiluted blood serum. Overall, these results highlight the advantages of using oligo-T(s) as a tunable linker to control flexibility of the tethered redox label, so as to achieve the desired sensor response.
KW - Electrochemical DNA sensor
KW - Linear probe, Stem-loop probe
KW - Methylene blue
KW - Mismatch discrimination
KW - Serum
UR - http://www.scopus.com/inward/record.url?scp=84894906492&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84894906492&partnerID=8YFLogxK
U2 - 10.1016/j.aca.2013.12.040
DO - 10.1016/j.aca.2013.12.040
M3 - Article
C2 - 24491779
AN - SCOPUS:84894906492
SN - 0003-2670
VL - 812
SP - 176
EP - 183
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
ER -