TY - JOUR
T1 - Effect of sampling frequency on fractal fluctuations during treadmill walking
AU - Marmelat, Vivien
AU - Duncan, Austin
AU - Meltz, Shane
N1 - Funding Information:
This work was supported by the Center for Research in Human Movement Variability of the University of Nebraska at Omaha (NIH P20GM109090, https://www.nih.gov/) to VM. The funder had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Publisher Copyright:
© 2019 Marmelat et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2019/11/1
Y1 - 2019/11/1
N2 - The temporal dynamics of stride-to-stride fluctuations in steady-state walking reveal important information about locomotor control and can be quantified using so-called fractal analyses, notably the detrended fluctuation analysis (DFA). Gait dynamics are often collected during treadmill walking using 3-D motion capture to identify gait events from kinematic data. The sampling frequency of motion capture systems may impact the precision of event detection and consequently impact the quantification of stride-to-stride variability. This study aimed i) to determine if collecting multiple walking trials with different sampling frequency affects DFA values of spatiotemporal parameters during treadmill walking, and ii) to determine the reliability of DFA values across downsampled conditions. Seventeen healthy young adults walked on a treadmill while their gait dynamics was captured using different sampling frequency (60, 120 and 240 Hz) in each condition. We also compared data from the highest sampling frequency to downsampled versions of itself. We applied DFA to the following time series: step length, time and speed, and stride length, time and speed. Reliability between experimental conditions and between downsampled conditions were measured with 1) intraclass correlation estimates and their 95% confident intervals, calculated based on a single-measurement, absolute-agreement, two-way mixed-effects model (ICC 3,1), and 2) Bland-Altman bias and limits of agreement. Both analyses revealed a poor reliability of DFA results between conditions using different sampling frequencies, but a relatively good reliability between original and downsampled spatiotemporal variables. Collectively, our results suggest that using sampling frequencies of 120 Hz or 240 Hz provide similar results, but that using 60 Hz may alter DFA values. We recommend that gait kinematics should be collected at around 120 Hz, which provides a compromise between event detection accuracy and processing time.
AB - The temporal dynamics of stride-to-stride fluctuations in steady-state walking reveal important information about locomotor control and can be quantified using so-called fractal analyses, notably the detrended fluctuation analysis (DFA). Gait dynamics are often collected during treadmill walking using 3-D motion capture to identify gait events from kinematic data. The sampling frequency of motion capture systems may impact the precision of event detection and consequently impact the quantification of stride-to-stride variability. This study aimed i) to determine if collecting multiple walking trials with different sampling frequency affects DFA values of spatiotemporal parameters during treadmill walking, and ii) to determine the reliability of DFA values across downsampled conditions. Seventeen healthy young adults walked on a treadmill while their gait dynamics was captured using different sampling frequency (60, 120 and 240 Hz) in each condition. We also compared data from the highest sampling frequency to downsampled versions of itself. We applied DFA to the following time series: step length, time and speed, and stride length, time and speed. Reliability between experimental conditions and between downsampled conditions were measured with 1) intraclass correlation estimates and their 95% confident intervals, calculated based on a single-measurement, absolute-agreement, two-way mixed-effects model (ICC 3,1), and 2) Bland-Altman bias and limits of agreement. Both analyses revealed a poor reliability of DFA results between conditions using different sampling frequencies, but a relatively good reliability between original and downsampled spatiotemporal variables. Collectively, our results suggest that using sampling frequencies of 120 Hz or 240 Hz provide similar results, but that using 60 Hz may alter DFA values. We recommend that gait kinematics should be collected at around 120 Hz, which provides a compromise between event detection accuracy and processing time.
UR - http://www.scopus.com/inward/record.url?scp=85074631868&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85074631868&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0218908
DO - 10.1371/journal.pone.0218908
M3 - Article
C2 - 31697684
AN - SCOPUS:85074631868
SN - 1932-6203
VL - 14
JO - PloS one
JF - PloS one
IS - 11
M1 - e0218908
ER -