In this research, solar energy has been stored using the paraffin with the latent heat technique for heating the plastic greenhouse of 180 m2. Energy and exergy analyses were applied for evaluation of the system efficiency. An average values of the rates of heat and thermal exergy stored into the HSU were 1 740 W and 60 W for the charging periods. It was determined that the average values of the net energy and exergy efficiencies of the system were 41.9 % and 3.3 %, respectively.

Original languageEnglish (US)
Pages (from-to)691-694
Number of pages4
JournalRenewable Energy
Volume16
Issue number1-4
DOIs
StatePublished - 1999

Keywords

  • Energy and exergy efficiencies
  • Greenhouse heating
  • Solar energy storage

ASJC Scopus subject areas

  • Renewable Energy, Sustainability and the Environment

Fingerprint Dive into the research topics of 'Energetic and exergetic efficiency of latent heat storage system for greenhouse heating'. Together they form a unique fingerprint.