TY - JOUR
T1 - How accurate are the wrist-based heart rate monitors during walking and running activities? Are they accurate enough?
AU - Stahl, Sarah E.
AU - An, Hyun Sung
AU - Dinkel, Danae M.
AU - Noble, John M.
AU - Lee, Jung Min
N1 - Publisher Copyright:
© Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
PY - 2016
Y1 - 2016
N2 - Background Heart rate (HR) monitors are valuable devices for fitness-orientated individuals. There has been a vast influx of optical sensing blood flow monitors claiming to provide accurate HR during physical activities. These monitors are worn on the arm and wrist to detect HR with photoplethysmography (PPG) techniques. Little is known about the validity of these wearable activity trackers. Aim Validate the Scosche Rhythm (SR), Mio Alpha (MA), Fitbit Charge HR (FH), Basis Peak (BP), Microsoft Band (MB), and TomTom Runner Cardio (TT) wireless HR monitors. Methods 50 volunteers (males: n=32, age 19-43 years; females: n=18, age 19-38 years) participated. All monitors were worn simultaneously in a randomised configuration. The Polar RS400 HR chest strap was the criterion measure. A treadmill protocol of one 30 min bout of continuous walking and running at 3.2, 4.8, 6.4, 8.0, and 9.6 km/h (5 min at each protocol speed) with HR manually recorded every minute was completed. Results For group comparisons, the mean absolute percentage error values were: 3.3%, 3.6%, 4.0%, 4.6%, 4.8% and 6.2% for TT, BP, RH, MA, MB and FH, respectively. Pearson product-moment correlation coefficient (r) was observed: r=0.959 (TT), r=0.956 (MB), r=0.954 (BP), r=0.933 (FH), r=0.930 (RH) and r=0.929 (MA). Results from 95% equivalency testing showed monitors were found to be equivalent to those of the criterion HR (±10% equivalence zone: 98.15-119.96). Conclusions The results demonstrate that the wearable activity trackers provide an accurate measurement of HR during walking and running activities.
AB - Background Heart rate (HR) monitors are valuable devices for fitness-orientated individuals. There has been a vast influx of optical sensing blood flow monitors claiming to provide accurate HR during physical activities. These monitors are worn on the arm and wrist to detect HR with photoplethysmography (PPG) techniques. Little is known about the validity of these wearable activity trackers. Aim Validate the Scosche Rhythm (SR), Mio Alpha (MA), Fitbit Charge HR (FH), Basis Peak (BP), Microsoft Band (MB), and TomTom Runner Cardio (TT) wireless HR monitors. Methods 50 volunteers (males: n=32, age 19-43 years; females: n=18, age 19-38 years) participated. All monitors were worn simultaneously in a randomised configuration. The Polar RS400 HR chest strap was the criterion measure. A treadmill protocol of one 30 min bout of continuous walking and running at 3.2, 4.8, 6.4, 8.0, and 9.6 km/h (5 min at each protocol speed) with HR manually recorded every minute was completed. Results For group comparisons, the mean absolute percentage error values were: 3.3%, 3.6%, 4.0%, 4.6%, 4.8% and 6.2% for TT, BP, RH, MA, MB and FH, respectively. Pearson product-moment correlation coefficient (r) was observed: r=0.959 (TT), r=0.956 (MB), r=0.954 (BP), r=0.933 (FH), r=0.930 (RH) and r=0.929 (MA). Results from 95% equivalency testing showed monitors were found to be equivalent to those of the criterion HR (±10% equivalence zone: 98.15-119.96). Conclusions The results demonstrate that the wearable activity trackers provide an accurate measurement of HR during walking and running activities.
KW - Assessing physiological demands of physical activity
KW - Assessing validity and reliability of test of physiological parameters
KW - Health promotion
KW - Physical activity
KW - Validity
UR - http://www.scopus.com/inward/record.url?scp=85032915160&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85032915160&partnerID=8YFLogxK
U2 - 10.1136/bmjsem-2015-000106
DO - 10.1136/bmjsem-2015-000106
M3 - Article
C2 - 27900173
AN - SCOPUS:85032915160
SN - 2055-7647
VL - 2
JO - BMJ Open Sport and Exercise Medicine
JF - BMJ Open Sport and Exercise Medicine
IS - 1
M1 - e000106
ER -