T1 - Multicenter evaluation of the BioFire FilmArray gastrointestinal panel for etiologic diagnosis of infectious gastroenteritis
AU - Buss, Sarah N.
AU - Leber, Amy
AU - Chapin, Kimberle
AU - Fey, Paul D.
AU - Bankowski, Matthew J.
AU - Jones, Matthew K.
AU - Rogatcheva, Margarita
AU - Kanack, Kristen J.
AU - Bourzac, Kevin M.
N1 - Publisher Copyright:
Copyright © 2015, American Society for Microbiology. All Rights Reserved..
PY - 2015/3/1
Y1 - 2015/3/1
N2 - The appropriate treatment and control of infectious gastroenteritis depend on the ability to rapidly detect the wide range of etiologic agents associated with the disease. Clinical laboratories currently utilize an array of different methodologies to test for bacterial, parasitic, and viral causes of gastroenteritis, a strategy that suffers from poor sensitivity, potentially long turnaround times, and complicated ordering practices and workflows. Additionally, there are limited or no testing methods routinely available for most diarrheagenic Escherichia coli strains, astroviruses, and sapoviruses. This study assessed the performance of the FilmArray Gastrointestinal (GI) Panel for the simultaneous detection of 22 different enteric pathogens directly from stool specimens: Campylobacter spp., Clostridium difficile (toxin A/B), Plesiomonas shigelloides, Salmonella spp., Vibrio spp., Vibrio cholerae, Yersinia enterocolitica, enteroaggregative E. Coli, enteropathogenic E. Coli, enterotoxigenic E. Coli, Shiga-like toxin-producing E. Coli (stx1 and stx2) (including specific detection of E. Coli O157), Shigella spp./enteroinvasive E. Coli, Cryptosporidium spp., Cyclospora cayetanensis, Entamoeba histolytica, Giardia lamblia, adenovirus F 40/41, astrovirus, norovirus GI/GII, rotavirus A, and sapovirus. Prospectively collected stool specimens (n=1,556) were evaluated using the BioFire FilmArray GI Panel and tested with conventional stool culture and molecular methods for comparison. The FilmArray GI Panel sensitivity was 100% for 12/22 targets and >94.5% for an additional 7/22 targets. For the remaining three targets, sensitivity could not be calculated due to the low prevalences in this study. The FilmArray GI Panel specificity was >97.1% for all panel targets. The FilmArray GI Panel provides a comprehensive, rapid, and streamlined alternative to conventional methods for the etiologic diagnosis of infectious gastroenteritis in the laboratory setting. The potential advantages include improved performance parameters, a more extensive menu of pathogens, and a turnaround time of as short as 1 h.
AB - The appropriate treatment and control of infectious gastroenteritis depend on the ability to rapidly detect the wide range of etiologic agents associated with the disease. Clinical laboratories currently utilize an array of different methodologies to test for bacterial, parasitic, and viral causes of gastroenteritis, a strategy that suffers from poor sensitivity, potentially long turnaround times, and complicated ordering practices and workflows. Additionally, there are limited or no testing methods routinely available for most diarrheagenic Escherichia coli strains, astroviruses, and sapoviruses. This study assessed the performance of the FilmArray Gastrointestinal (GI) Panel for the simultaneous detection of 22 different enteric pathogens directly from stool specimens: Campylobacter spp., Clostridium difficile (toxin A/B), Plesiomonas shigelloides, Salmonella spp., Vibrio spp., Vibrio cholerae, Yersinia enterocolitica, enteroaggregative E. Coli, enteropathogenic E. Coli, enterotoxigenic E. Coli, Shiga-like toxin-producing E. Coli (stx1 and stx2) (including specific detection of E. Coli O157), Shigella spp./enteroinvasive E. Coli, Cryptosporidium spp., Cyclospora cayetanensis, Entamoeba histolytica, Giardia lamblia, adenovirus F 40/41, astrovirus, norovirus GI/GII, rotavirus A, and sapovirus. Prospectively collected stool specimens (n=1,556) were evaluated using the BioFire FilmArray GI Panel and tested with conventional stool culture and molecular methods for comparison. The FilmArray GI Panel sensitivity was 100% for 12/22 targets and >94.5% for an additional 7/22 targets. For the remaining three targets, sensitivity could not be calculated due to the low prevalences in this study. The FilmArray GI Panel specificity was >97.1% for all panel targets. The FilmArray GI Panel provides a comprehensive, rapid, and streamlined alternative to conventional methods for the etiologic diagnosis of infectious gastroenteritis in the laboratory setting. The potential advantages include improved performance parameters, a more extensive menu of pathogens, and a turnaround time of as short as 1 h.
UR - http://www.scopus.com/inward/record.url?scp=84923376418&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84923376418&partnerID=8YFLogxK
U2 - 10.1128/JCM.02674-14
DO - 10.1128/JCM.02674-14
M3 - Article
C2 - 25588652
AN - SCOPUS:84923376418
SN - 0095-1137
VL - 53
SP - 915
EP - 925
JO - Journal of clinical microbiology
JF - Journal of clinical microbiology
IS - 3
ER -