Self-sterilization of the electrosurgery electrode

David H. Shaw, Kenneth L. Kalkwarf, Robert F. Krejci, Allen R. Edison

Research output: Contribution to journalArticle

2 Scopus citations

Abstract

Sterilization of the electrode used in electrosurgery has been assumed to occur at the instant of contact of the energized electrode tip to a grounded source. This study evaluated whether the time of electrode activation or the amount of energy delivered is important in the self-sterilization process. Standard bacteriologic culturing techniques were employed to assess sterility of the electrode tip following activation. Total time of application of the current and the energy used were recorded on audiotape and later tabulated. The data indicate that the time of energizing and the energy units used are critical in the sterilization of the electrode tip. These results confirm that self-sterilization of the electrosurgery electrode tip occurs, but full confidence is not realized with the time intervals commonly employed in clinical practice. The electrode tip must be considered a potential source of bacterial contamination of electrosurgically managed dental procedures.

Original languageEnglish (US)
Pages (from-to)290-292
Number of pages3
JournalOral Surgery, Oral Medicine, Oral Pathology
Volume66
Issue number3
DOIs
StatePublished - Sep 1988

ASJC Scopus subject areas

  • Pathology and Forensic Medicine
  • Dentistry(all)

Fingerprint Dive into the research topics of 'Self-sterilization of the electrosurgery electrode'. Together they form a unique fingerprint.

  • Cite this