TY - JOUR
T1 - Systematic characterization of high mass accuracy influence on false discovery and probability scoring in peptide mass fingerprinting
AU - Dodds, Eric D.
AU - Clowers, Brian H.
AU - Hagerman, Paul J.
AU - Lebrilla, Carlito B.
N1 - Funding Information:
Funds provided by the following sources are gratefully acknowledged: National Institutes of Health grants AG 24488 (to P.J.H.) and GM 49077 (to C.B.L.), California Dairy Research Foundation grant 06 LEC-01-NH (to C.B.L.), and a grant from Dairy Management Incorporated.
PY - 2008/1/15
Y1 - 2008/1/15
N2 - Whereas the bearing of mass measurement error on protein identification is sometimes underestimated, uncertainty in observed peptide masses unavoidably translates to ambiguity in subsequent protein identifications. Although ongoing instrumental advances continue to make high accuracy mass spectrometry (MS) increasingly accessible, many proteomics experiments are still conducted with rather large mass error tolerances. In addition, the ranking schemes of most protein identification algorithms do not include a meaningful incorporation of mass measurement error. This article provides a critical evaluation of mass error tolerance as it pertains to false positive peptide and protein associations resulting from peptide mass fingerprint (PMF) database searching. High accuracy, high resolution PMFs of several model proteins were obtained using matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR-MS). Varying levels of mass accuracy were simulated by systematically modulating the mass error tolerance of the PMF query and monitoring the effect on figures of merit indicating the PMF quality. Importantly, the benefits of decreased mass error tolerance are not manifest in Mowse scores when operating at tolerances in the low parts-per-million range but become apparent with the consideration of additional metrics that are often overlooked. Furthermore, the outcomes of these experiments support the concept that false discovery is closely tied to mass measurement error in PMF analysis. Clear establishment of this relation demonstrates the need for mass error-aware protein identification routines and argues for a more prominent contribution of high accuracy mass measurement to proteomic science.
AB - Whereas the bearing of mass measurement error on protein identification is sometimes underestimated, uncertainty in observed peptide masses unavoidably translates to ambiguity in subsequent protein identifications. Although ongoing instrumental advances continue to make high accuracy mass spectrometry (MS) increasingly accessible, many proteomics experiments are still conducted with rather large mass error tolerances. In addition, the ranking schemes of most protein identification algorithms do not include a meaningful incorporation of mass measurement error. This article provides a critical evaluation of mass error tolerance as it pertains to false positive peptide and protein associations resulting from peptide mass fingerprint (PMF) database searching. High accuracy, high resolution PMFs of several model proteins were obtained using matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR-MS). Varying levels of mass accuracy were simulated by systematically modulating the mass error tolerance of the PMF query and monitoring the effect on figures of merit indicating the PMF quality. Importantly, the benefits of decreased mass error tolerance are not manifest in Mowse scores when operating at tolerances in the low parts-per-million range but become apparent with the consideration of additional metrics that are often overlooked. Furthermore, the outcomes of these experiments support the concept that false discovery is closely tied to mass measurement error in PMF analysis. Clear establishment of this relation demonstrates the need for mass error-aware protein identification routines and argues for a more prominent contribution of high accuracy mass measurement to proteomic science.
KW - False positive
KW - Fourier transform ion cyclotron resonance mass spectrometry
KW - Mass measurement accuracy
KW - Matrix-assisted laser desorption/ionization
KW - Peptide mass fingerprinting
UR - http://www.scopus.com/inward/record.url?scp=36148937543&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=36148937543&partnerID=8YFLogxK
U2 - 10.1016/j.ab.2007.10.009
DO - 10.1016/j.ab.2007.10.009
M3 - Article
C2 - 17980142
AN - SCOPUS:36148937543
VL - 372
SP - 156
EP - 166
JO - Analytical Biochemistry
JF - Analytical Biochemistry
SN - 0003-2697
IS - 2
ER -