TY - JOUR
T1 - Test-retest reliability and minimal detectable change of the computerized dynamic posturography PROPRIO for adults with chronic traumatic brain injury
AU - Cesar, Guilherme M.
AU - Buster, Thad W.
AU - Burnfield, Judith M.
N1 - Funding Information:
This study was funded, in part, by The Bill Kubly student research scholarship awarded to Thad W. Buster.
Publisher Copyright:
© 2019 Informa UK Limited, trading as Taylor & Francis Group.
PY - 2021
Y1 - 2021
N2 - Purpose: Balance deficits after brain injury, including reactive recovery from unexpected perturbations, can persist well after rehabilitation is concluded. While traditional clinical assessments are practical, the anticipatory nature of the tasks may mask perceptible balance control. Computerized dynamic posturography can directly quantify capacity to respond to unexpected, external perturbations. This study examined the reliability of the computerized dynamic posturography assessment with the device PROPRIO® 4000 in adults with traumatic brain injury and created the minimal detectable change for its standardized test. Methods: Ten adults (ages 21–55 years) with chronic (average 10 ± 6 years post-injury) severe (loss of consciousness 2–75 days) brain injury performed three trials of the Propriotest® on two separate days. The average of three trials and the best scores were used separately for analysis. Test-retest reliability was verified using Intraclass Correlation Coefficients with 95% confidence interval and standard error of measurement in relation to the Intraclass Correlation Coefficients at 95%. The minimal detectable change was calculated at 95% confidence level (minimal detectable change95) and Bland-Altman plots were created to express agreement between measurement days. Results: The results exhibited excellent reliability for both average (Intraclass Correlation Coefficient of 0.969, standard error of measurement 50.9 points) and best (Intraclass Correlation Coefficient of 0.985, standard error of measurement 31.3 points) scores, with average and best minimal detectable change95 of 141.0 and 86.7 points, respectively. Conclusions: Clinicians and rehabilitation researchers can use these findings to determine if a Propriotest® change score represents a true post-treatment effect with adults with chronic brain injury.IMPLICATIONS FOR REHABILITATION After brain injury, balance deficits are common and can persist well after completion of rehabilitation programs. Computerized dynamic posturography allows for objective quantification of one’s capacity to respond to external perturbations. The device PROPRIO® 4000 provides reliable quantification of balance deficits of community dwelling individuals who have experienced a severe traumatic brain injury. The minimal detectable change scores created can assist clinicians and rehabilitation researchers detect whether a change in balance score represents a true effect of an intervention at post-treatment.
AB - Purpose: Balance deficits after brain injury, including reactive recovery from unexpected perturbations, can persist well after rehabilitation is concluded. While traditional clinical assessments are practical, the anticipatory nature of the tasks may mask perceptible balance control. Computerized dynamic posturography can directly quantify capacity to respond to unexpected, external perturbations. This study examined the reliability of the computerized dynamic posturography assessment with the device PROPRIO® 4000 in adults with traumatic brain injury and created the minimal detectable change for its standardized test. Methods: Ten adults (ages 21–55 years) with chronic (average 10 ± 6 years post-injury) severe (loss of consciousness 2–75 days) brain injury performed three trials of the Propriotest® on two separate days. The average of three trials and the best scores were used separately for analysis. Test-retest reliability was verified using Intraclass Correlation Coefficients with 95% confidence interval and standard error of measurement in relation to the Intraclass Correlation Coefficients at 95%. The minimal detectable change was calculated at 95% confidence level (minimal detectable change95) and Bland-Altman plots were created to express agreement between measurement days. Results: The results exhibited excellent reliability for both average (Intraclass Correlation Coefficient of 0.969, standard error of measurement 50.9 points) and best (Intraclass Correlation Coefficient of 0.985, standard error of measurement 31.3 points) scores, with average and best minimal detectable change95 of 141.0 and 86.7 points, respectively. Conclusions: Clinicians and rehabilitation researchers can use these findings to determine if a Propriotest® change score represents a true post-treatment effect with adults with chronic brain injury.IMPLICATIONS FOR REHABILITATION After brain injury, balance deficits are common and can persist well after completion of rehabilitation programs. Computerized dynamic posturography allows for objective quantification of one’s capacity to respond to external perturbations. The device PROPRIO® 4000 provides reliable quantification of balance deficits of community dwelling individuals who have experienced a severe traumatic brain injury. The minimal detectable change scores created can assist clinicians and rehabilitation researchers detect whether a change in balance score represents a true effect of an intervention at post-treatment.
KW - Balance
KW - brain injury
KW - computerized dynamic posturography
KW - minimal detectable change
KW - rehabilitation
KW - reliability
UR - http://www.scopus.com/inward/record.url?scp=85075219498&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85075219498&partnerID=8YFLogxK
U2 - 10.1080/09638288.2019.1688872
DO - 10.1080/09638288.2019.1688872
M3 - Article
C2 - 31724889
AN - SCOPUS:85075219498
SN - 0963-8288
VL - 43
SP - 2038
EP - 2044
JO - Disability and Rehabilitation
JF - Disability and Rehabilitation
IS - 14
ER -