Wear of mobile bearing knees: Is it necessarily less?

Hani Haider, Christian Kaddick

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

Some well-known mobile bearing designs have had truly excellent long-term clinical results. Their lower constraint and ability for some self-alignment might have helped reduce the shear forces and torques transmitted to the prosthesis-bone interface, thereby lowering the risk of loosening. However, the most commonly assumed benefit of mobile bearings is the reduction in wear due to less contact stress and reduced cross shear. In a rotating platform, wear can be reduced because the rolling/sliding motion is separated from the transverse rotational motion, which reduces cross-shear. Although it has not been categorically proven clinically, such lower wear expectations with mobile bearings might have influenced the thinking of some total knee replacement (TKR) designers and test engineers. This paper amalgamates in vitro TKR wear results from two separate laboratories (in Nebraska and Germany) to present the largest data set ever published on wear, across the widest variety of fixed and mobile bearing TKR designs. Many hundreds of TKR samples were tested with largely similar methodologies using the ISO 14243-1 force-control method. These tests covered 133 different fixed and mobile bearing designs and materials, in total (bicondylar) and unicompartmental forms, and of a wide range of sizes. Clear differences in wear resulted with known superior bearing materials. This illustrates how sensitive and capable of discriminating between low and high wearing implants the force-control wear testing methodology is. However, between both labs, and across all tests, no statistically significant differences were found in wear overall between fixed and mobile bearings. Therefore, the wear of mobile bearing knees is not necessarily less than that of fixed bearings. In both, it depends on the detailed design and materials of the TKR. Testing appears to be necessary with all implant designs, regardless of the history of clinically successful predicates of seemingly similar generic design.

Original languageEnglish (US)
JournalJournal of ASTM International
Volume9
Issue number2
DOIs
StatePublished - Feb 2012

Keywords

  • Fixed bearing
  • In vitro testing
  • Knee simulator
  • Mobile bearing
  • Rotating platform
  • TKR
  • Total knee replacement
  • Wear

ASJC Scopus subject areas

  • Environmental Engineering
  • General Materials Science
  • Nuclear Energy and Engineering
  • General Engineering
  • Public Health, Environmental and Occupational Health

Fingerprint

Dive into the research topics of 'Wear of mobile bearing knees: Is it necessarily less?'. Together they form a unique fingerprint.

Cite this