TY - JOUR
T1 - Wearing a safety harness during treadmill walking influences lower extremity kinematics mainly through changes in ankle regularity and local stability
AU - Decker, Leslie M.
AU - Cignetti, Fabien
AU - Stergiou, Nicholas
N1 - Funding Information:
LD is supported by the National Institutes of Health (1K99AG033684). FC and NS are supported by the National Institute on Disability and Rehabilitation Research (H133G080023). The authors thank Maris L. Hokes for her assistance in collecting data.
PY - 2012
Y1 - 2012
N2 - Background: Wearing a harness during treadmill walking ensures the subject's safety and is common practice in biomedical engineering research. However, the extent to which such practice influences gait is unknown. This study investigated harness-related changes in gait patterns, as evaluated from lower extremity kinematics during treadmill walking. Findings. Healthy subjects (n = 10) walked on a treadmill at their preferred speed for 3 minutes with and without wearing a harness (LiteGait, Mobility Research, Inc.). In the former condition, no weight support was provided to the subjects. Lower extremity kinematics was assessed in the sagittal plane from the mean (mean RoM), standard deviation (SD RoM) and coefficient of variation (CoV RoM) of the hip, knee, and ankle ranges of motion (RoM), as well as from the sample entropy (SampEn) and the largest Lyapunov exponent (LyE) of the joints' angles. Wearing the harness increased the mean RoMof the hip, the SD RoMand the CoV RoMof the knee, and the SampEn and the LyE of the ankle. In particular, the harness effect sizes for both the SampEn and the LyE of the ankle were large, likely reflecting a meaningful decline in the neuromuscular stabilizing control of this joint. Conclusions: Wearing a harness during treadmill walking marginally influences lower extremity kinematics, resulting in more or less subtle changes in certain kinematic variables. However, in cases where differences in gait patterns would be expressed through modifications in these variables, having subjects walk with a harness may mask or reinforce such differences.
AB - Background: Wearing a harness during treadmill walking ensures the subject's safety and is common practice in biomedical engineering research. However, the extent to which such practice influences gait is unknown. This study investigated harness-related changes in gait patterns, as evaluated from lower extremity kinematics during treadmill walking. Findings. Healthy subjects (n = 10) walked on a treadmill at their preferred speed for 3 minutes with and without wearing a harness (LiteGait, Mobility Research, Inc.). In the former condition, no weight support was provided to the subjects. Lower extremity kinematics was assessed in the sagittal plane from the mean (mean RoM), standard deviation (SD RoM) and coefficient of variation (CoV RoM) of the hip, knee, and ankle ranges of motion (RoM), as well as from the sample entropy (SampEn) and the largest Lyapunov exponent (LyE) of the joints' angles. Wearing the harness increased the mean RoMof the hip, the SD RoMand the CoV RoMof the knee, and the SampEn and the LyE of the ankle. In particular, the harness effect sizes for both the SampEn and the LyE of the ankle were large, likely reflecting a meaningful decline in the neuromuscular stabilizing control of this joint. Conclusions: Wearing a harness during treadmill walking marginally influences lower extremity kinematics, resulting in more or less subtle changes in certain kinematic variables. However, in cases where differences in gait patterns would be expressed through modifications in these variables, having subjects walk with a harness may mask or reinforce such differences.
UR - http://www.scopus.com/inward/record.url?scp=84856421048&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84856421048&partnerID=8YFLogxK
U2 - 10.1186/1743-0003-9-8
DO - 10.1186/1743-0003-9-8
M3 - Article
C2 - 22305105
AN - SCOPUS:84856421048
SN - 1743-0003
VL - 9
JO - Journal of NeuroEngineering and Rehabilitation
JF - Journal of NeuroEngineering and Rehabilitation
IS - 1
M1 - 8
ER -